InstrumentsPressure and temperature measurementT +49 40 5247 4156 · M +49 176 3130 5711sales@eurekaeu.com
Stainless dairy process skid with pressure gauges, a control panel and a plate heat exchanger

Home / Applications / Food and pharma

Industry · Food and pharma

Hygienic instruments for food processing and pharmaceutical plants

Pressure gauges with clamp diaphragm seals, polished clamp thermometers, pressure transmitters and Pt100 sensors – for pumps, filters, separators, tanks, vessels and homogenisers. Specified to your connection and surface requirements – and quoted by us.

  • Clamp connections to ISO 2852
  • Polished AISI 316 wetted parts
  • Gauges for homogenisers
  • Inert-gas filled thermometers
Ra ≤ 0.8 µmpolished sensor; Ra ≤ 0.5 µm electropolished
−40 … +250 °Cpolished clamp thermometer
1½" / 2"clamp to ISO 2852
Class 1.0homogeniser gauge to EN 837-1

Requirements

What a hygienic line asks of an instrument

Hygiene, cleaning and the process connection decide the instrument. These are the points we check with you before we quote – all values from the manufacturer’s datasheets.

01

Measuring points

  • Pumps, filters, separators, tanks, vessels and homogenisers
  • Pressure and temperature in hygienic applications
02

Hygienic connections

  • Clamp diaphragm seals to ISO 2852 (clamp connection)
  • In-line seals with clamp or knuckle-thread union
  • Seals made to ISO, DIN, ASME, RJT, IDF and other standards
03

Surfaces and materials

  • Wetted parts in AISI 316
  • Thermometer sensor polished to Ra ≤ 0.8 µm, electropolished Ra ≤ 0.5 µm as an option
  • Thermometer filled with inert gas (argon)
04

Homogenisers

  • Gauge with diaphragm seal designed for homogenisers – liquid filled and pulsation damped
  • Over-range protection FS +1000 bar (max. 2000 bar) at media temperature below 40 °C
  • DN 100, AISI 316 case, EN 837-1 class 1.0
05

Temperature

  • Polished clamp thermometer DN 100, −40 to +250 °C, class 1 to EN 13190
  • Sensor Ø 10 or 13 mm; with 13 mm, minimum L 100 mm for 50 mm immersion
  • Pt100 temperature sensors and a mechatronic thermometer up to 300 °C
06

Signals

  • Pressure transmitter with plug or cable
  • Pressure gauge with 4–20 mA output or alarm contacts
  • Heavy-duty differential pressure transmitter
✓

Documentation

Tell us which certificates, material documents and fill-fluid declarations your plant requires. We confirm per model what can be supplied and state it in the quotation.

In service

Where hygienic instruments work

Stainless pressure gauge with a clamp diaphragm seal
Gauge with clamp diaphragm seal
Hygienic valve block with two pressure gauges
Valve block with gauges
Stainless process skid with gauges in a food plant
Process skid

Photos show typical installations. Image credits.

Typical applications

How instruments are typically used in food and pharma

Two common scenarios. They describe typical installations, not a specific plant or customer.

Pressure gauge with clamp diaphragm seal
Scenario 1

Pressure on a product line with clamp connections

On a hygienic line, the instrument connects with the same clamp as the rest of the pipework.

  1. A gauge with a clamp diaphragm seal to ISO 2852 mounts directly on the line.
  2. The diaphragm seal separates the product from the measuring element.
  3. Where the control system needs the value, a pressure transmitter or a gauge with 4–20 mA output is used.

What we need from you: clamp size, range, product temperature, surface requirement and output.

Hygienic valve block with two pressure gauges
Scenario 2

Outlet pressure at a homogeniser

A homogeniser works at high pressure with strong pulsation.

  1. A DN 100 gauge with a diaphragm seal designed for homogenisers is liquid filled and pulsation damped.
  2. Over-range protection up to FS +1000 bar (max. 2000 bar) at media temperature below 40 °C.
  3. Options: remote reading with capillary, built-in contact or built-in 4–20 mA transmitter.

What we need from you: range, connection to the homogeniser, media temperature and options.

Engineering

Technical notes and common faults

General engineering points we check with you. They are not a guarantee for a specific installation.

Dead spaces

Threads and gaps hold product and cleaning agent. Flush clamp or in-line seals avoid dead space at the measuring point.

Cleaning temperature

CIP and SIP cycles load seal, fill liquid and case. Tell us the cleaning temperature and duration.

Fill liquid in contact areas

If a diaphragm fails, fill liquid can reach the product. State which fill-fluid declarations your plant requires.

Documents

Datasheet with the quotation. Calibration documents and, where available for the product type, certificates are confirmed per model. Resources and checklists →

Why FEX

What you get with us

Seal and gauge from one manufacturer

The diaphragm seal and the gauge are made by the same manufacturer, so the two parts are designed to work together.

Hand-calibrated thermometers

Each polished clamp thermometer is manufactured with care and hand calibrated.

Built to your specification

Standard products and customer-specified versions come from one modular system – ranges, threads, fills and mounting to suit the measuring point.

One contact in Hamburg

Selection, quotation, documentation, shipping to your site and after-sales – coordinated from Hamburg.

Send us your hygienic specification

  1. Product and process temperature
  2. Range and unit
  3. Clamp or hygienic connection size
  4. Surface finish
  5. Output: dial, signal or contacts
  6. Quantity and delivery country

Ready to specify an instrument?

Send us the measuring point and requirements – we reply with a written quotation and the matching datasheet.