For local temperature reading on engines, tanks and pipework.

Dial thermometers are quoted to your range, stem and connection. Full datasheet on request.

Request a quote

Dial thermometer with rigid stem

Available range

Measuring ranges−80 to +500 °C. Polished clamp version −40 to +250 °C; mechatronic exhaust-gas version up to 650 °C.
Accuracy classClass 1 to EN 13190
Nominal size / dialDN 80 and DN 100
Process connectionRigid stem, remote reading with capillary 0.5–50 m, or ISO 2852 clamp
Wetted materialsSensor tubes and capillary armour in AISI 316
Case / IPRigid-stem version IP 68 (10 mH₂O)
FillingPolished clamp version filled with inert gas (argon)
Output signalLocal dial
OptionsMechatronic version: dial plus type K thermocouple in one stem

Full datasheet on request.

Versions we quote

Each version is configured to your range, connection and documents. The model is confirmed in the quotation.

Rigid-stem dial thermometer

Local reading on engines, tanks and pipework.

DN 80 / DN 100 · IP 68 (10 mH₂O)

Add to RFQ →

Remote-reading thermometer

Capillary in AISI 316 for a reading away from the measuring point.

Capillary 0.5–50 m

Add to RFQ →

Polished clamp thermometer

Hygienic lines, filled with inert gas (argon).

DN 100 · −40 to +250 °C · ISO 2852

Add to RFQ →

Mechatronic thermometer

Dial and type K thermocouple in one stem.

Exhaust-gas version up to 650 °C

Add to RFQ →

Typical applications

Dial thermometer with °C scale on an engine cooling-water pipe

Engines and pipework

A local temperature reading on the engine or the pipe.

Dial thermometer on a stainless hot-water storage tank

Tanks and heaters

A dial on the tank or the heater.

Dial thermometer on a polished stainless pipe in a hygienic process hall

Hygienic lines

A local reading on a food or pharmaceutical line.

Photos show typical installations. Image credits.

How to specify

  1. Medium and temperature
  2. Measuring range and unit
  3. Process connection
  4. Output: dial, signal, sensor or contacts
  5. Quantity and delivery country

Questions

What should I send?

Medium, range, connection and quantity. We reply to the email you give.

Where is the datasheet?

Full datasheet on request, with the quotation.

Who answers?

Our sales desk in Hamburg, at sales@eurekaeu.com.