Rigid-stem dial thermometer
Local reading on engines, tanks and pipework.
DN 80 / DN 100 · IP 68 (10 mH₂O)
For local temperature reading on engines, tanks and pipework.
Dial thermometers are quoted to your range, stem and connection. Full datasheet on request.

| Measuring ranges | −80 to +500 °C. Polished clamp version −40 to +250 °C; mechatronic exhaust-gas version up to 650 °C. |
|---|---|
| Accuracy class | Class 1 to EN 13190 |
| Nominal size / dial | DN 80 and DN 100 |
| Process connection | Rigid stem, remote reading with capillary 0.5–50 m, or ISO 2852 clamp |
| Wetted materials | Sensor tubes and capillary armour in AISI 316 |
| Case / IP | Rigid-stem version IP 68 (10 mH₂O) |
| Filling | Polished clamp version filled with inert gas (argon) |
| Output signal | Local dial |
| Options | Mechatronic version: dial plus type K thermocouple in one stem |
Full datasheet on request.
Each version is configured to your range, connection and documents. The model is confirmed in the quotation.
Local reading on engines, tanks and pipework.
DN 80 / DN 100 · IP 68 (10 mH₂O)
Capillary in AISI 316 for a reading away from the measuring point.
Capillary 0.5–50 m
Hygienic lines, filled with inert gas (argon).
DN 100 · −40 to +250 °C · ISO 2852
Dial and type K thermocouple in one stem.
Exhaust-gas version up to 650 °C

A local temperature reading on the engine or the pipe.

A dial on the tank or the heater.

A local reading on a food or pharmaceutical line.
Photos show typical installations. Image credits.
Medium, range, connection and quantity. We reply to the email you give.
Full datasheet on request, with the quotation.
Our sales desk in Hamburg, at sales@eurekaeu.com.