InstrumentsPressure and temperature measurementT +49 40 5247 4156 · M +49 176 3130 5711sales@eurekaeu.com

Resources

Checklists and technical notes for specifying an instrument. Datasheets and order documents come with the quotation.

Specification checklists

Copy the list for your family into the enquiry, or upload your own RFQ file.

Pressure gauge

  • Medium and medium temperature
  • Working range, unit, pressure peaks and overpressure
  • Accuracy class and dial size
  • Process connection and position (bottom or rear)
  • Filling: dry, glycerine or silicone
  • Options: contacts, 4–20 mA, safety pattern

Details · Add to RFQ →

Pressure transmitter

  • Medium and medium temperature
  • Range, overpressure and pressure transients
  • Output signal and supply
  • Electrical connection: plug or cable
  • Process connection
  • Ambient conditions: vibration, marine, hazardous area

Details · Add to RFQ →

Thermometer

  • Temperature range
  • Dial size
  • Rigid stem or remote reading; capillary length
  • Stem diameter and immersion length
  • Thermowell or direct mounting
  • Hygienic connection if needed

Details · Add to RFQ →

Temperature sensor

  • Element: Pt100 or thermocouple type
  • Range at the measuring point
  • Probe length and diameter
  • Connection head and cable
  • Thermowell
  • Input of the control system

Details · Add to RFQ →

Diaphragm seal

  • Medium, temperature and cleaning cycle
  • Connection: clamp, dairy thread, in-line or flange
  • Diaphragm material
  • Fill liquid and its declarations
  • Gauge or transmitter to be mounted
  • Documents required

Details · Add to RFQ →

Pressure switch

  • Medium
  • Set point and switching direction
  • Electrical load
  • Contact type
  • Process connection
  • Environment

Details · Add to RFQ →

Technical notes

Range and overpressure

Choose a range so the normal working pressure stays well below full scale. State pressure peaks and overpressure separately – they decide the measuring element and any protection.

Accuracy class

For pressure gauges to EN 837-1 the accuracy class is the permissible error as a percentage of the span. Class 1.0 means 1 % of the span.

Liquid filling

Glycerine or silicone filling damps pulsation and vibration and protects the movement. Dry gauges are used where filling is not wanted.

When to use a diaphragm seal

Use a seal when the medium is hot, viscous, crystallising, aggressive or hygienic. The seal keeps the medium away from the measuring element.

Pt100 or thermocouple

Pt100 resistance sensors are common for moderate temperatures. Thermocouples are used for high temperatures such as exhaust gas. The input of your system decides.

Immersion and thermowells

The stem has to reach the flow to read correctly. A thermowell lets you change the instrument without opening the process.

Documents

  • Datasheet: sent with the quotation for the configured instrument.
  • Calibration documents: confirmed per order.
  • Material, traceability and 3.1 inspection documents: can be supplied for instruments with diaphragm seals; confirmed at quotation.
  • Certificates: where available for the product type, confirmed per model in the quotation. We do not publish certificate copies on this site.

Glossary

DN
Nominal size of the dial, in millimetres.
EN 837-1
European standard for Bourdon-tube pressure gauges.
EN 13190
European standard for dial thermometers.
ISO 2852
Clamp connection used on hygienic lines.
DIN 11851
Dairy thread connection.
Duplex gauge
Two pressures on one dial.
Differential gauge
Shows the difference between two pressures.
Safety pattern
Gauge with a blow-out back that protects the reader if the element fails.
Pt100
Platinum resistance sensor, 100 Ω at 0 °C.
Type K
Nickel-chromium / nickel thermocouple.

Ready to send your specification?

Upload your RFQ, drawing or datasheet with the enquiry form, or write to sales@eurekaeu.com.

Upload RFQ