Industry · HVAC

Instruments for heating, cooling and air-handling plant

Dial thermometers and pressure gauges for local reading on pumps, manifolds and heat exchangers, low-pressure gauges in mbar and kPa, plus contact gauges, switches and Pt100 sensors for the building management system. Specified to your circuit – and quoted by us.

  • Dial thermometers −80 to +500 °C
  • Low-pressure gauges in mbar and kPa
  • Gauges with alarm contacts
  • Pt100 sensors for the BMS
DN 63 – 160pressure gauge dial sizes
−80 … +500 °Cdial thermometer range
0.5 – 50 mcapillary for remote reading
Class 1thermometers to EN 13190

Requirements

What a plant room asks of an instrument

Circuit, mounting position and the signal to the BMS decide the instrument. These are the points we check with you before we quote – all values from the manufacturer’s datasheets.

01

Typical measuring points

  • Flow and return temperature on heating and cooling circuits
  • Pressure at circulation pumps, manifolds and heat exchangers
  • Low and differential pressure at filters and in air ducts
02

Thermometers

  • Rigid-stem or remote-reading dial thermometers
  • −80 to +500 °C, class 1 to EN 13190
  • Capillary 0.5 to 50 m in AISI 316 for a reading away from the measuring point
03

Pressure gauges

  • DN 63 to DN 160, class 1.0 (DN 63: 1.6)
  • Units such as bar, kPa, mH₂O and psi
  • Bottom or rear connection; direct, wall or panel mounting
04

Low and differential pressure

  • Low-pressure gauges with a stainless bellows system, scales in mbar or kPa
  • High pointer torque, suitable for built-in contact systems
  • Differential pressure gauges and differential pressure switches
05

Signals to the BMS

  • Pt100 resistance sensors and thermocouples
  • Pressure transmitters with plug or cable
  • Gauges with alarm contacts and pressure switches

In service

Where HVAC instruments work

Combined pressure and temperature gauge on a heating line
Pressure and temperature on one dial
Insulated heating and cooling distribution header with pressure gauges and dial thermometers in a plant room
Distribution header in a plant room
Plant room with insulated heating and cooling circuits, pressure gauges and dial thermometers
Plant room with insulated circuits
Dial thermometers on insulated riser pipes
Thermometers on risers

Photos show typical installations. Image credits.

Typical applications

How instruments are typically used in HVAC

Two common scenarios. They describe typical installations, not a specific building or customer.

Insulated heating and cooling distribution header with pressure gauges and dial thermometers in a plant room
Scenario 1

Flow and return on a heating manifold

Flow and return temperature and the system pressure are the readings a technician checks first.

  1. A dial thermometer in flow and in return shows the temperature difference on site.
  2. A pressure gauge at the manifold shows the system pressure next to the circulation pump.
  3. Where the BMS needs the value, a Pt100 sensor measures at the same point.

What we need from you: range, stem length or capillary, connection thread and the signal your BMS expects.

Dial thermometers on riser pipes
Scenario 2

Thermometers on risers and distribution pipes

Several pipes side by side are easier to compare when every dial has the same range and size.

  1. Rigid-stem dial thermometers with the same range on each riser.
  2. Where the measuring point is hard to reach, a remote-reading thermometer with a capillary of up to 50 m puts the dial on a panel.
  3. Ranges, stems and threads come from one modular system.

What we need from you: number of points, ranges, stem length or capillary and connection.

Engineering

Technical notes and common faults

General engineering points we check with you. They are not a guarantee for a specific installation.

Too short immersion length

A stem that does not reach the flow reads low. Pipe size and thermowell length decide the stem length.

Working pressure at full scale

A gauge that sits at the top of its scale wears fast. The range is chosen so the working pressure stays well below full scale.

Signal mismatch at the BMS

Sensor element and signal must match the building management system. Name the BMS input on the enquiry.

Documents

Datasheet with the quotation. Calibration documents and, where available for the product type, certificates are confirmed per model. Resources and checklists →

Why FEX

What you get with us

Calibrated one by one

Each pressure gauge is calibrated manually and individually at five points on the scale, upwards and downwards. Bourdon tubes are heat-treated to reduce hysteresis.

Built to your specification

Standard products and customer-specified versions come from one modular system – ranges, threads, fills and mounting to suit the measuring point.

Documents with the order

Datasheet with the quotation. Calibration documents and, where available for the product type, certificates are prepared to match your order.

One contact in Hamburg

Selection, quotation, documentation, shipping to your site and after-sales – coordinated from Hamburg.

Send us your HVAC specification

  1. Medium and temperature
  2. Range and unit
  3. Stem length or capillary
  4. Connection and mounting
  5. Output: dial, signal or contacts
  6. Quantity and delivery country

Ready to specify an instrument?

Send us the measuring point and requirements – we reply with a written quotation and the matching datasheet.